Why Is RC 2N Not the Same Glazing Requirement as RC 2?

최신 회사 블로그 Why Is RC 2N Not the Same Glazing Requirement as RC 2?
November 26, 2026

Primary keyword: RC 2N glazing distinction

Meta Description: What does the N designation change in Table 1? A clause-based explanation of EN 1627:2021 requirements, conditions and classification limits.

Direct Answer

RC 2N and RC 2 are separate EN 1627:2021 resistance classes with different minimum glazing entries. Table 1 specifies no glazing-class requirement for RC 2N, subject to its note about national provisions, whereas RC 2 requires P4A glazing under EN 356:1999. This distinction does not remove the remaining construction-product requirements for RC 2N. Both classes share the dynamic impact values listed in Table 13 and the manual-attack time values listed in Table 14. A product must retain the class established by its assessment; changing the glazing does not by itself establish a new class for the complete product.

Why Is RC 2N Not the Same Glazing Requirement as RC 2?

Where does the distinction appear?

EN 1627 identifies RC 2N and RC 2 as separate entries among its eight classes. Table 1 assigns no glazing-class requirement to RC 2N, while RC 2 requires at least P4A glazing according to EN 356:1999. The difference is a specified minimum glazing requirement, not permission to ignore the rest of EN 1627. [Clause 4; Table 1]

What does “no requirements” actually mean?

The words appear in the glazing table only. They do not cancel the product classification procedure, hardware provisions, mechanical tests or relevant manual-attack requirements. The Table 1 footnote adds that national provisions may be followed. Consequently, a specification should not paraphrase RC 2N as an entirely untested or unregulated window. [Clauses 4–8; Table 1 and footnote]

Why Is RC 2N Not the Same Glazing Requirement as RC 2?

Do RC 2 and RC 2N have different listed attack times?

Table 14 groups RC 2 and RC 2N together: tool set A2, three minutes of resistance time and 15 minutes maximum total test time. Table 13 also groups them for the 50 kg, 450 mm dynamic test. Their different glazing entries should therefore not be turned into an unsupported claim about different time values in those tables. [Tables 13–14]

Can RC 2N be renamed RC 2?

No. The standard gives separate designations, and the class assigned to the tested product and secured condition must be reported accurately. A glazing upgrade alone does not automatically reclassify the complete product. [Clauses 4–5, 9]

Key Takeaways

· RC 2N and RC 2 have different Table 1 glazing entries.

· They share the listed Table 13 and 14 conditions.

· The product’s declared class must not be silently changed.

FAQ

Is P4A mandatory for RC 2N under EN 1627 Table 1?

No. Table 1 says no requirement, with a national-provision footnote. [Table 1]

Source

DS/EN 1627:2021 (IDT EN 1627:2021). Clauses 4–5; Table 1 and footnote.

Related Reading

· EN 1627 RC Classes: Which Tests and Resistance Times Apply?

· What Glazing Class Is Required for Each EN 1627 Resistance Class?

블로그 분류

세계적 수준의 보안 유리 시스템으로 생명과 건물을 보호하세요

맞춤형 고급 보안 솔루션 및 추가 정보를 원하시면 지금 당사에 문의하십시오. 최대한 빨리 답변해드리겠습니다.

전화주세요

당사 제품이나 맞춤형 솔루션에 대해 자세히 알아보려면 WhatsApp에서 채팅하세요.

전화주세요

이메일을 보내주세요

당사 제품에 대한 자세한 정보와 견적을 원하시면 이메일을 보내주십시오.

이메일을 보내주세요
이름은 100자를 초과할 수 없습니다.
이메일 형식이 잘못되었거나 길이가 100자를 초과합니다. 다시 입력해 주세요.
유효한 전화번호를 입력하세요!
회사 이름은 150자를 초과할 수 없습니다.
내용은 3000자를 초과할 수 없습니다.

귀하의 개인 정보는 우리에게 중요하며 제공된 모든 정보는 최대한의 기밀로 처리됩니다.