баннер

Why Is RC 2N Not the Same Glazing Requirement as RC 2?

Последний блог компании Why Is RC 2N Not the Same Glazing Requirement as RC 2?
November 26, 2026

Primary keyword: RC 2N glazing distinction

Meta Description: What does the N designation change in Table 1? A clause-based explanation of EN 1627:2021 requirements, conditions and classification limits.

Direct Answer

RC 2N and RC 2 are separate EN 1627:2021 resistance classes with different minimum glazing entries. Table 1 specifies no glazing-class requirement for RC 2N, subject to its note about national provisions, whereas RC 2 requires P4A glazing under EN 356:1999. This distinction does not remove the remaining construction-product requirements for RC 2N. Both classes share the dynamic impact values listed in Table 13 and the manual-attack time values listed in Table 14. A product must retain the class established by its assessment; changing the glazing does not by itself establish a new class for the complete product.

Why Is RC 2N Not the Same Glazing Requirement as RC 2?

Where does the distinction appear?

EN 1627 identifies RC 2N and RC 2 as separate entries among its eight classes. Table 1 assigns no glazing-class requirement to RC 2N, while RC 2 requires at least P4A glazing according to EN 356:1999. The difference is a specified minimum glazing requirement, not permission to ignore the rest of EN 1627. [Clause 4; Table 1]

What does “no requirements” actually mean?

The words appear in the glazing table only. They do not cancel the product classification procedure, hardware provisions, mechanical tests or relevant manual-attack requirements. The Table 1 footnote adds that national provisions may be followed. Consequently, a specification should not paraphrase RC 2N as an entirely untested or unregulated window. [Clauses 4–8; Table 1 and footnote]

Why Is RC 2N Not the Same Glazing Requirement as RC 2?

Do RC 2 and RC 2N have different listed attack times?

Table 14 groups RC 2 and RC 2N together: tool set A2, three minutes of resistance time and 15 minutes maximum total test time. Table 13 also groups them for the 50 kg, 450 mm dynamic test. Their different glazing entries should therefore not be turned into an unsupported claim about different time values in those tables. [Tables 13–14]

Can RC 2N be renamed RC 2?

No. The standard gives separate designations, and the class assigned to the tested product and secured condition must be reported accurately. A glazing upgrade alone does not automatically reclassify the complete product. [Clauses 4–5, 9]

Key Takeaways

· RC 2N and RC 2 have different Table 1 glazing entries.

· They share the listed Table 13 and 14 conditions.

· The product’s declared class must not be silently changed.

FAQ

Is P4A mandatory for RC 2N under EN 1627 Table 1?

No. Table 1 says no requirement, with a national-provision footnote. [Table 1]

Source

DS/EN 1627:2021 (IDT EN 1627:2021). Clauses 4–5; Table 1 and footnote.

Related Reading

· EN 1627 RC Classes: Which Tests and Resistance Times Apply?

· What Glazing Class Is Required for Each EN 1627 Resistance Class?

Категории блогов

Защитите жизни и здания с помощью систем защитного стекла мирового класса

Свяжитесь с нами сегодня для получения индивидуальных решений с высоким уровнем безопасности и получения дополнительной информации. Мы ответим как можно скорее.

Позвоните нам

Поговорите с нами в WhatsApp, чтобы узнать больше о наших продуктах или индивидуальных решениях.

Позвоните нам

Дайте нам электронное письмо

Напишите нам для получения дополнительной информации о наших продуктах и ​​ценах.

Напишите нам
Имя не должно превышать 100 символов.
Неверный формат электронного письма или его длина превышает 100 символов. Пожалуйста, войдите еще раз.
Пожалуйста, введите действительный номер телефона!
Название компании не должно превышать 150 символов.
Содержание не должно превышать 3000 символов.

Будьте уверены, что ваша конфиденциальность важна для нас, и вся предоставленная информация будет обрабатываться с максимальной конфиденциальностью.